AQ-S254 Alarm and indication device

The AQ-S254 alarm and indication device can be applied to various substation tasks: extending the general I/O, sounding alarms, and control. You can add up to fourteen (14) I/O or communication cards into the device, depending on the requirements of your application. The logic programming is powerful and easy to use. It also further expands the device’s application range towards more demanding control, alarm and indication needs. The HMI is large and can be freely programmed, and provides a quick visualization of the object as well as the status of alarms and events.

Read More
Description:

AQ-S254 communicates using various protocols, including the IEC 61850 substation communication standard.

Highlights:
  • Modern alarm sounding and I/O extension with IEC 61850 and GOOSE communication.
  • Control and status indication for 20 objects.
  • A full mimic diagram with busbar coloring.
  • A full-color display for up to 128 alarms.

Technical Data

  • Number of objects to control and monitor: 10
  • Number of indicators to monitor: 20
  • Number of alarms to program: 128
  • Number of setting groups: 8

  • Event recorder (max. 15 000 permanent event records)
  • Disturbance recorder (max. 100 records á 5 seconds at 3.2 kHz sampling)

  • Digital inputs (fixed): 3
  • Digital outputs (fixed): 5
  • Number of empty slots: 14
  • Digital inputs: +8/16/24/32/40/48/56/64/72/80/88/96/104/112 (optional)
  • Digital outputs: +5/10/15/20/25/30 (optional)
  • Milliampere I/O module (4 mA outputs + 1 mA input)
  • Communication media (see "Communication" below)
  • External I/O modules (see "Accessories" below)

  • Communication inputs
  • RJ-45 100 Mbps Ethernet (front panel, fixed)
  • RJ-45 100 Mbps Ethernet and RS-485 (rear panel, fixed)
  • 2 x RJ-45 100 Mbps Ethernet with an IRIG-B input (optional)
  • 2 x ST 100 Mbps Ethernet with an IRIG-B input (optional)
  • 2 x LC 100 Mbps Ethernet (PRP/HSR) (optional)
  • RS-232 serial fiber (PP/PG/GP/GG) (optional)
  • Communication protocols
  • IEC 61850 (edition 1)
  • IEC 61850 (edition 2)
  • IEC 60870-5-101/104
  • IEC 60870-5-103
  • Modbus/RTU and Modbus/TCP
  • DNP3
  • SPA

  • AX007 External 6-channel 2-/3-wire RTD input module (pre-configured)
  • AX008 External 8-channel thermocouple and mA input module (pre-configured)
  • AX013 Raising frame (120 mm)
  • AX014 Raising frame (40 mm)
  • AX015 Wall mounting bracket
  • Are you a serious well-wisher of your production unit? know the emotions from our existing customers.
  • Would you wish critical spares be always in-hands ensuring continuous plant operations without any interruption?
  • Would you like to receive your machineries / routine spares at most economical pricing?
  • How expensive is peace of mind having Arc fault free electrical systems in your premises?

Reach us to know

Request a call back